| Analysis of Transient Electromagnetic exploration Technology for water accumulated in goaf of Huayang No.2 Mine |
| Li Jun |
| No.2 Mine of Shanxi Huayang Group Xinneng Resources Co., Ltd.,Yangquan 045008, China |
|
|
|
|
Abstract The water accumulated in the overlying goaf of the coal mining face is the water source condition that causes the water outburst accident. In order to ensure the safe mining of No.21051 face in Huayang No.2 Mine, the position relationship and characteristics between No.21051 face and overlying No.3 coal seam working face goaf were analyzed, and the transient electromagnetic exploration was carried out. An abnormal area was obtained by transient electromagnetic exploration in the upper roadway. The roof exploration drilling hole was constructed at 1 180 m of the upper roadway, and the water accumulated in goaf of 27 821 m3 was drained, which ensured the safe mining of the working face. The study provided experience for the detection of water accumulation range in similar roof goaf.
|
|
|
|
|
|
| [ 1 ] 董书宁,虎维岳. 中国煤矿水害基本特征及其主要影响因
素[ J ]. 煤田地质与勘探,2007( 5 ):34 - 38.
[ 2 ] 陈江峰,黄玉峰,熊法政. 承压水导升过程中微裂隙扩张分析[ J ]. 地质与勘探,2017,53( 1 ):157 - 163.
[ 3 ] 马亚杰,冯 玉,章之燕,等. 煤层底板强含水层超前疏放分析与应用[ J ]. 煤炭学报,2014( 4 ):731 - 735.
[ 4 ] 栾元重,李静涛,班训海,等. 近距煤层开采覆岩导水裂隙带高度观测研究[ J ]. 采矿与安全工程学报,2010( 1 ):139 - 142. |
|
|
|