Abstract Aiming at the dust concentration of 206 working face in Dianping Mine as high as 166 mg/m3 during mining, which resulted in low visibility and misoperation of the equipment, the dust removal measures and problems were analyzed, with the optimization of the dust removal technology. The dust density was below 57 mg/m3 and the working face visibility was up to 30 m after the technology, with obvious effect.
|