| Raw-milk freezing point testers indication error measurement result uncertainty evaluation |
| Hong Chuan |
| Hebei Institute of Meterology, Shijiazhuang 050000, China |
|
|
|
|
Abstract The indication error of raw milk freezing point testers was detected by using national standard reference materials. The uncertainty of indication error and measurement result is evaluated through the establishment of mathematical model, which is including the uncertainty introduced by measurement repeatability, reference materials and instrument resolution. When the measuring point: -400、-408、-450、-500、-512、-520、-557、-600 m ℃, the expanded uncertainty 0.8,1.0,1.0,0.9,1.0,1.0,1.0,1.1 m ℃(k=2).
|
|
|
|
|
|
| [ 1 ] 张小伟,满金龙. 生鲜牛奶的冰点检测[ J ]. 现代畜牧兽药,2005( 8 ):25.
[ 2 ] 王永康,曹国华. 生牛奶质量中的冰点问题[ J ]. 中国乳业,2003( 8 ):30 - 32.
[ 3 ] JJF 1816-2020,生乳冰点仪校准规范[ S ].
[ 4 ] CNAS-GL06:2006,化学分析中的不确定度评定指南[ S ].
[ 5 ] JJF 105.1-2012,测量不确定度评定与表示[ S ]. |
|
|
|