| Causes analysis and improved measures of the bed leakage of molecular sieve adsorber in MTO |
| Wu Tengteng1, Cheng Xiaoge2, Yuan Jinlin1, Li Chenguo1 |
| 1. Sinopec Great Wall Energy Chemical (Guizhou) Corporation Ltd., Guiyang 550000, China; 2. Graduate School of Chemistry and Chemical Engineering, Guizhou University, Guiyang 550000, China |
|
|
|
|
Abstract In order to solve the problems of molecular sieve leakage and pipe blockage in molecular sieve adsorber in start-up stage of new plant. The leakage during the operation of molecular sieve is described in detail,and through the analysis of molecular sieve loading, internal component inspection, operation parameters and so on,the problems in the process of molecular sieve loading, internal fixation of adsorber, pressure relief and liquid drainage were discussed. After the MTO plant shutdown, by the means of technical transformation and adjustment of operating pressure,the similar phenomenon was not occurred in the MTO plant. The results show that the qualified installation of molecular sieve bed bottom support and Wilson grid plate are quite important, the pressure relief and liquid drainage of molecular sieve adsorber is controlled at 0.1 MPa, the regeneration temperature is lower than 225 ℃, which is beneficial to the long and stable operation.
|
|
|
|
|
|
| [ 1 ] 陈 旭. 吸附工艺在碳捕集中的应用现状[ J ]. 中国电机工程学报,2019,39( S1 ):155 - 163.
[ 2 ] 王 玲. 分子筛三环桥结构的发现可能有助于合成新分子筛应用于清洁能源和碳捕集领域[ J ]. 石油炼制与化工,2020,51( 8 ):36 - 36.
[ 3 ] 高腾飞. 碳捕集变压吸附技术工艺及吸附材料研究进展[ J ]. 辽宁化工,2020,49( 11 ):1 389 - 1 394.
[ 4 ] 刘慧敏.分子筛的选型与比较[ J ]. 天然气技术与经济, 2011,5( 3 ):47 - 49,79.
[ 5 ] 褚衍资. 低压羰基法合成丁醇转化器催化剂的装填及检验方法[ J ]. 化工设计通讯,2014,40( 4 ):64 - 66.
[ 6 ] 习小华. 分子筛严重粉化原因分析[ J ]. 深冷技术,2015
( 1 ):14 - 15.
[ 7 ] 高 伟. 降低分子筛吸烃损失技术研究[ D ]. 吉林:吉林大
学,2014:35 - 70.
[ 8 ] 黄 焜. 分子筛露点波动分析与研究[ J ]. 中小企业管理与科技,2015( 11 ):257 - 257.
[ 9 ] 李季明. 13X型分子筛用于高压空气干燥时吸附极限露点的测定[ J ]. 流体机械,2002,( 1 ):8 - 10. |
|
|
|