| Engineering design for reconstruction of gas-making circulating water system |
| Fan Xu |
| Shanxi Yangmei Coal Chemical Engineering Corporation Ltd., Taiyuan 030021, China |
|
|
|
|
Abstract The process of "closed micro-vortex clarifier + closed cooling tower" was used to treat the original circulating water system for gas production. Because gas making circulating water adopts direct cooling method, water quality is poor, which can easy to cause corrosion and blockage of pipelines and equipment and so on. Closed micro-vortex clarifier and cooling tower often stop for maintenance, which is not conducive to the stable operation of the system. The existing system was reformed by adopting the method of "Advection Sedimentation Tank + Open Cooling Tower", At the same time considering a certain margin,and keeping the old system in reserve.
|
|
|
|
|
|
| [ 1 ] 沈宏伟. 造气循环水处理工艺研究[ J ]. 山东化工,2018,( 4 ):141 - 143.
[ 2 ] 陈 伟. 造气污水冷却塔技术改造[ J ]. 河南科技,2013,( 10 ):12 - 13.
[ 3 ] GB/50014-2021,室外排水设计标准[ S ].
[ 4 ] GB/50015-2019,建筑给水排水设计标准[ S ].
[ 5 ] 张玉先. 给水工程[ M ]. 北京:中国建筑工业出版社,2015:4.
[ 6 ] 何 强. 龙腾锐. 排水工程[ M ]. 北京:中国建筑工业出版社,2015:4. |
|
|
|