Abstract Based on three times of Ordovician limestone water in deep mining area of Xingdong Mine, Ordovician limestone water threatened deep more than shallow, directional close horizontal branch drilling group technology was proposed. Based on exploration and control of water structure of vertical guide, tectonic zone, fracture zone and water-rich abnormal area were explored and grouting. The technology cuts off the supply of Ordovician limestone water and ensures the safe mining.
|