| Investigation and protection of chloride ion stress corrosion cracking of heat exchanger |
| Wang Dezhou, Liu Zengwen, Yang Jianjie |
| Zaozhuang Jiefuyi Zhenxing Chemical Corporation Ltd., Zaozhuang 277000, China |
|
|
|
|
Abstract In order to avoid the leakage of heat exchanger caused by chloride ion stress corrosion, prolong the service life of heat exchanger and ensure the stability and continuity of chemical production, by analyzing the material, structure and production process of heat exchanger, the characteristic of corrosion leakage of heat exchanger is determined as chloride ion stress corrosion. By optimizing and adjusting the material, structure and process index of the heat exchanger, the leakage caused by chloride stress corrosion was avoided.The test results show that the economy and continuity of chemical production are significantly enhanced by eliminating chloride ion stress corrosion of heat exchanger, which can create greater benefits for enterprises
|
|
|
|
|
|
| [ 1 ] 刘园园,吴 烜,孙阳庭,等. 不锈钢点蚀与缝隙腐蚀评价技术研究及其应用[ J ]. 上海金属,2020,42( 6 ):66 - 73.
[ 2 ] 王立坤,陈 海,魏培生,等. 不锈钢换热管的失效分析[ J ]. 腐蚀与防护,2020,41( 10 ):74 - 78.
[ 3 ] 孙树强,王维革. 不锈钢板式换热器失效原因及提高使用寿命方法探究[ J ]. 中国设备工程,2020( 9 ):146 - 147.
[ 4 ] 王家文. 不锈钢氯离子应力腐蚀开裂分析[ J ]. 特种设备安全技术,2019( 2 ):56 - 57.
[ 5 ] 王家文,张伟刚. 不锈钢氯离子应力腐蚀开裂分析[ J ]. 化工管理,2019( 10 ):96 - 97.
[ 6 ] 张国亮. 大唐克旗煤制天然气公司换热器氯离子腐蚀泄漏解决方案[ J ]. 化工设计通讯,2019,45( 7 ):231 - 233.
[ 7 ] 丁顺利. 换热器换热管氯离子应力腐蚀开裂事故案例分析[ J ]. 中国特种设备安全,2018,34( 7 ):61 - 66.
[ 8 ] 董绍平,循环水不锈钢换热器抗氯离子应力腐蚀研究[ J ]. 石油化工腐蚀与防护,2012,29( 1 ):36 - 40. |
|
|
|