| Study on cephalosporin antibiotic wastewater treatment technology |
| Wang Mingbo1, Wang Qi1, Liu Guoxin2, Zhang Junli1 |
| 1. Beta Branch Factory, North China Pharmaceutical Corporation Ltd., Shijiazhuang 050000, China; 2. Hebei Chemical Industry Research Institute Corporation Ltd., Shijiazhuang 050000, China |
|
|
|
|
Abstract The composition of cephalosporin antibiotic wastewater is complex and it’s more difficult to treat it. According to the composition and property of the wastewater, the process of reduced pressure distillation, extraction and rectification were used to recycle organic base with economically valuable. The optimal process parameters were determined. The experimental results show that the COD treatment rate in wastewater can reach 75%, toluene dosage, sodium hydroxide dosage and extraction time are the key factors affecting the yield of organic base. The optimized process conditions are that 2.5 m3 of toluene is added to each batch of wastewater, the sodium hydroxide input is 580 kg, and the extraction time is 40 min. The total recovery rate of organic base is up to 52% and the purity is over 99%. The treatment process is simple and convenient, the equipment is easy to operate and runs stably.
|
|
|
|
|
|
| [ 1 ] 巩有奎,张林生. 抗生素废水处理研究进展[ J ]. 工业水处理,2005,25( 12 ):1 - 5.
[ 2 ] 杨 军,陆正禹,胡纪萃,等. 抗生素工业废水生物处理技术的现状与展望[ J ]. 环境科学,1997,18( 3 ):83.
[ 3 ] 曾丽璇,张秋云,刘佩红,等. 抗生素制药废水处理技术进展. 安全与环境工程,2005,12( 4 ):62 - 65.
[ 4 ] 刘国信,叶康钰,夏恒霞. 制药废水中水回收金霉素的研究[ J ]. 水处理技术,1995,21( 2 ):85 - 88.
[ 5 ] 巩有奎,张林生. 抗生素废水处理研究进展[ J ]. 工业水处理,2005,25( 12 ):1 - 5.
[ 6 ] 唐受印. 废水处理工程[ M ]. 北京:化学工业出版社,1998:1 - 10.
[ 7 ] 饶义平,唐文浩. 复合絮凝处理抗生素废水对其抑菌效力的影响[ J ]. 上海环境科学,1996,15( 8 ):37.
[ 8 ] 李尔炀. 工程菌处理制药废水[ J ]. 水处理技术,2001,27( 5 ):287 - 289. |
|
|
|