Application of five figure double coefficient method in water burst evaluation of Beixinyao Mine floor
Wang Zongming1, Lai Yongwei2, Duan Jianjun1
1. No. 3 Geology Team, China National Administration of Coal Geology, Handan 056006, China; 2. No. 1 Geological Survey Institute, China National Administration of Coal Geology, Handan 056004, China
Beixinyao Mine is in construction, there is floor water burst in +1 040 mlevel south wing return air roadway mining, the maximum water inflow reaches 455 m3/h, the position is considered as safe area by water burst coefficient method, which shows the method alone is not precise enough to evaluate the geological condition. Based on the sufficient analysis of coalfield geological condition, by analyzing the factors affecting floor water burst like inrush floor damage depth, bottom layer thickness, water distribution and effective protective thickness, etc, five figure double coefficient method is applied to evaluate the floor Ordovician limestone, the prediction result provides reference for water prevention and control.
王宗明,来永伟,段俭君. 五图双系数法在北辛窑煤矿底板突水评价中的应用[J]. 煤炭与化工, 2016, 39(5): 7-12,17.