| Application of transient electromagnetic advanced detection technology in No.9103 detection roadway of Xingtai Mine |
| Liu Jian1,2,3, Zhang Dong1,2,3 |
| 1.Hebei Coal Research Institute Co., Ltd., Xingtai 054000, China;2. Key Laboratory of Mine Water Disaster Detection and Prevention and Control State Mine Safety Supervision Bureau,Xingtai 054000, China; 3.Hebei Mine Geophysical Exploration Engineering Center,Xingtai 054000, China |
|
|
|
|
Abstract No.9103 detection roadway in the west well of Xingtai Mine is the No.9 coal excavating roadway. According to the existing hydrogeological data and comprehensive analysis of No.9100 mining area, the hydrogeological conditions of the working face are clear and the fault structure is developed. Quaternary bottom gravel water, Benxi limestone water and Ordovician limestone water are the water filling sources of No.9 coal floor in No.9103 Face. The transient electromagnetic advanced detection position was located in the opening of the roadway, with seven angles detected in the horizontal direction and seven angles detected in the vertical direction. According to the detection results, there was a relatively low-resistance area in the detection range. It was verified by the mine drilling that the abnormal area was true and reliable.
|
|
|
|
|
|
| [ 1 ] 郭培鹏. 瞬变电磁超前探测技术在山西金谷煤矿中的应用[ J ]. 煤炭与化工,2015,38( 2 ):94 - 95.
[ 2 ] 尹松良. 邢台矿西井地面区域治理方案[ J ]. 煤炭与化工,2016,39( 12 ):62 - 64.
[ 3 ] 崔焕玉. 瞬变电磁在葛泉矿应用中的典型异常分析[ J ]. 煤炭与化工,2020,43( 10 ):60 - 63.
[ 4 ] 高小青. 大社矿921102工作面综合物探技术研究[ J ]. 煤炭与化工,2020,43( 8 ):56 - 58,62.
[ 5 ] 赵永亮. 强干扰环境下煤矿井下巷道瞬变电磁探测研究与应用[ J ]. 煤炭与化工,2023,46( 10 ):77 - 80.
[ 6 ] 赵永强. 东庞矿下组煤带压开采水文地质分析及防治水措施[ J ]. 煤炭与化工,2014,37( 9 ):100 - 103. |
|
|
|