| Research on the application of transient electromagnetic monitoring technology in working face affected by collapse column structure |
| Ji Jiyou |
| Shanxi Xinzhou Shenda Energy Group Co., Ltd., Xinzhou 034000, China |
|
|
|
|
Abstract The hydrogeological and structural conditions of No.1306 Face in Licun Coal Mine were complex, which put forward higher requirements for the exploration of water-bearing structure. In order to ensure the safety production of mine, the application test of mine transient electromagnetic monitoring technology was carried out. The advanced monitoring and positioning research was carried out in the excavating face of No.1306 air intake roadway to improve the accuracy of the positioning of the water abundance abnormal area and the accuracy of drainage by drilling, so as to ensure the work efficiency. The monitoring research on the drainage of the collapse column was carried out in the working face. The reliability of the delineation results of the low-resistance abnormal area was ensured by comparison and verification, and the drainage effect was verified, which provided reliable information for water disaster prevention and control in working face.
|
|
|
|
|
|
| [ 1 ] 马立军,王世常. 瞬变电磁法在探测永明煤矿地质构造中的应用[ J ]. 华北科技学院学报,2019,16( 2 ):25 - 29,44.
[ 2 ] 田海波. 瞬变电磁法在矿井采掘过程中的应用研究[ J ]. 煤矿现代化,2017( 5 ):39 - 41.
[ 3 ] 南莹浩,徐旭东. 大阳煤矿陷落柱区域富水性探测研究[ J ].华北科技学院学报,2017,14( 4 ):42 - 46.
[ 4 ] 任豫涛. 瞬变电磁法在构造探测中的应用[ J ]. 西部探矿工程,2015,27( 5 ):94 - 96. |
|
|
|