| Study on the width of waterproof coal pillar in No.15 coal seam of F14 fault in Shigang Coal Industry |
| Yue Jianwu |
| Shanxi Shigang Coal Industry Co., Ltd., Jinzhong 032600,China |
|
|
|
|
Abstract In order to ensure the safety production of No.15 coal seam under the influence of F14 fault in Shigang Mine, taking No.15212 fully mechanized mining face as the background, the width of waterproof coal pillar was studied. By means of data investigation, underground drilling and numerical simulation, the analysis showed that F14 fault belonged to weak water abundance and weak water conduction fault. It was suggested that the width of waterproof coal pillar of F14 fault was 30 m. Compared with the original design of 100 m wide waterproof coal pillar, it could increase the coal reserve by 454 000 t while ensuring the safety production of the working face, which had good economic and social benefits.
|
|
|
|
|
|
| [ 1 ] 左常清,刘亚楠,田晓伟. 义桥煤矿3305工作面断层防水煤柱安全评价[ J ]. 山东煤炭科技,2022,40( 11 ):169 - 171.
[ 2 ] 王 忻. 范各庄矿12~#煤层导水断层防水煤柱留设[ J ]. 煤炭技术,2020,39( 10 ):94 - 96.
[ 3 ] 谢华东,侯俊华,朱术云. 大型断层奥灰防水煤柱留设及其阻渗性探究[ J ]. 矿业工程研究,2020,35( 1 ):54 - 58.
[ 4 ] 田渊辉. 斜沟矿井下断层防水煤柱设置宽度的优化研究[ J ].山西化工,2019,39( 3 ):135 - 137. |
|
|
|