| Experimental study on treatment of waste emulsion by physicochemical method |
| Leng Chaoqun, Bian Wenqiang, Dong Tao, Yao Ruijing, Sun Huifeng |
| ENN Envirotech Corporation Ltd., Langfang 065001, China |
|
|
|
|
Abstract The waste emulsion was treated using demulsification and Fenton oxidation, and its influencing factors were studied systematically. The experimental results show when the dosage of calcium chloride was 5 g / L, the stirring time was 30 minutes, the dosage of PAC was 4 g / L, the dosage of APAM was 10 mg / L, the removal rate of COD was 67.38%. After demulsification and precipitation, Fenton oxidation was carried out under acidic conditions. The dosage of ferrous sulfate heptahydrate was 11.12 g / L, 30% hydrogen peroxide was 100 mL/L, and after three hours of reaction, calcium oxide and APAM were added for flocculation and sedimentation, the dosage of calcium oxide was 6.33 g / L, the dosage of APAM was10 mg / L, the COD was reduced to 1 731 mg / L, the removal rate of COD was 92.47%, BOD was decreased to 1 595 mg / L, B / C was 0.92, and the effiluent could enter the biochemical system directly.
|
|
|
|
|
|
| [ 1 ] 余林康. 机械加工乳化液废水治理综述[ J ]. 海峡科学,2013( 2 ):26 - 27.
[ 2 ] 徐 明,朱华军,胡 伟. 废乳化液利用处置技术概述[ J ].
山西建筑,2015,41( 17 ):203 - 205.
[ 3 ] 闰 莉,杨昌柱. 乳化含油废水处理方法研究[ J ]. 化学与生物工程,2003( 6 ):9 - 110.
[ 4 ] 田 禹,范丽娜. 盐析法处理高浓含油乳化液及其反应机制[ J ]. 中国给水排水,2004,20( 4 ):47 - 49.
[ 5 ] 王志强,李 黎,陈文清. 乳化液废水处理技术的综述研究[ J ]. 工业水处理,2012,32( 9 ):7 - 9.
[ 6 ] 邵 青,冷超群. 胶体滴定测定PAC电荷密度的实验研究[ J ]. 工业水处理,2014,34( 9 ):70 - 73.
[ 7 ] Chamarro E, Marco A, Esplugas S. Use of Fenton reagent to improve organic chemical biodegradability[ J ]. Water Res, 2001, 35( 4 ):1 047 - 1 051.
[ 8 ] Cláudia Telles Benatti, Célia Regina Granhen Tavares, Terezinha Aparecida Guedes. Optimization of Fenton's oxidation of chemical laboratory wastewaters using the response surface methodology[ J ]. Environmental Management, 2006, 80( 1 ):66 - 74.
[ 9 ] Ebru Cokay Catalkaya,Fikret Kargi. Advanced oxidation and mineralization of simazine using Fenton's reagent [ J ]. Hazardous Materials, 2009, 168( 2 - 3 ):688 - 694.
[ 10 ] Lodyga A, Minda-Data D, KozioL M. Using the deep oxidation process with fenton's reagent to remove formaldehyde from industrial wastewater [ J ]. Chemik, 2013, 67( 7 ):648 - 653.
[ 11 ] D P Mohapatra, S K Brar, R D Tyagi. A comparative study of ultrasonication, Fenton's oxidation and ferro-sonication treatment for degradation of carbamazepine from wastewater and toxicity test by Yeast Estrogen Screen( YES )assay[ J ]. Science of the Total Environment, 2013,447:280 - 285. |
|
|
|